Every instrument.
Every certificate. Zero surprises.
An overdue calibration is one of the easiest audit findings to prevent — and one of the most common, because tracking due dates in a spreadsheet depends on someone remembering to check it. ValiCore blocks new results from an out-of-cal instrument automatically.
What is calibration management software?
Calibration management software maintains a master register of every instrument requiring periodic calibration — balances, HPLCs, pH meters, thermometers, pipettes — tracking calibration frequency, last and next due dates, and storing the calibration certificate itself. The mature version of this goes further: it captures as-found and as-left readings at every calibration event, computes instrument status (OK/Due/Overdue) automatically, and blocks the instrument from generating new results once it goes out of tolerance or past its due date — closing the gap between 'we have a schedule' and 'the system enforces the schedule.'
Built for
What goes wrong without it
Overdue instruments keep generating results
Without an automatic block, nothing stops a technician from running a test on an instrument that's a week past its calibration due date — until an auditor cross-references the calibration log against the test log.
As-found data gets skipped
Recording only the as-left (post-adjustment) reading, without the as-found value, means you can never demonstrate whether the instrument was actually in tolerance before it was adjusted — a specific gap auditors check for.
Certificates live in a filing cabinet, not a system
When an inspector asks for the calibration certificate for a specific instrument on a specific date, "let me find the folder" is a worse answer than pulling it up in seconds.
What ValiCore actually does here
Master instrument register
Every instrument with its calibration frequency, last/next due date, and full certificate history in one place.
21 CFR 211.68Automatic overdue blocking
Instruments past their due date or out of tolerance are automatically flagged and blocked from logging new results.
As-found / as-left capture
Both readings recorded at every calibration event, alongside measurement uncertainty and applied tolerance.
ISO/IEC 1702530/60/90-day forecast calendar
A rolling calendar view of every calibration due in the next 90 days, for vendor coordination and internal scheduling.
NABL-traceable certificate storage
Certificates attached directly to the calibration record, with vendor name and traceability reference captured alongside.
21 CFR Part 11 e-signature + review
Calibration records carry a performer signature and an independent reviewer signature — the reviewer can never be the same person who performed the calibration.
21 CFR Part 11Out-of-tolerance impact assessment
An out-of-cal result automatically triggers an assessment of what other tests or batches that instrument may have affected.
Regulations this addresses
Frequently asked questions
The instrument is flagged out-of-tolerance and blocked from generating new results until re-calibrated and confirmed in range. Because the impact of an out-of-cal instrument isn't limited to the calibration event itself, an out-of-tolerance result should trigger an assessment of every test or batch the instrument touched since its last good calibration — this is the OOC (out-of-calibration) impact workflow.
As-found is the instrument's reading before any adjustment is made during calibration — it tells you whether the instrument was actually within tolerance during the period since its last calibration. As-left is the reading after adjustment. Recording only as-left (the common shortcut) means you can never demonstrate the instrument's real accuracy during the preceding usage period — exactly the detail an auditor will ask about.
Yes — a calibration due-date forecast should run automatically off each instrument's calibration frequency, without needing anyone to manually check a spreadsheet. ValiCore surfaces a 30/60/90-day forecast and flags anything overdue directly on the dashboard.